117/148
Connecting External Devices To The Door Station
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
Example: Connecting Up To Four Bell Buttons
Connect bell buttons:
• First wire to terminals 7.1 to 7.4 (1 to 4 bell buttons)
• Second wire to power supply
Connect power supply:
• First wire to terminal b
• Second wire to bell buttons
T24-OPT-IO
MX -
MX +
b
ERT
Do
iLi
eLi/c
eLi
Bpc
Dpc
Auth/S2
PIR
7.4
7.3
7.2
7.1
e.g. 12 V AC
power supply
1st doorbell button
Connect 2nd to 4th doorbell buttons
to 7.1 to 7.4 (similar to 7.1)