137/148
Installation In The Siedle Vario System
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
Door Contact And Door Lock Switch
Connect both with one connection each to c; connect the second connector of the door
contact to IO module Dpc (Door Position Contact); connect the second connector of the
door lock switch to IO module Bpc (Bolt Position Contact).
Note
The contacts can generally also be installed in existing doors. To do so, use a long
drill bit to drill a conduit in the door frame leading directly to an in-wall socket on the
wall facing the door inside the building, then lay a cable from here to the door station.
Siedle Anti-Theft Protection
The separately available Siedle Anti-Theft Protection module
(DSC 602-0 with ZDS 601-0) provides additional protection by
electromagnetically locking the installation frame so that the
individual modules can no longer be mechanically removed
(using the supplied Siedle key) from the door station.
The lock (ZDS 601-0) mounted in the installation frame is
connected to the associated controller (DSC 602-0) in the
electrical cabinet. Anti-theft protection can only be activated
or deactivated using this controller.
Installation instructions are included in the Siedle Anti-Theft
Protection package.
Board Module
Dpc Door contact
Board Module
Bpc
Door lock
switch