84/148
T24 System Manual Part 1: Installation
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
2.4.2 Installing The T24-KeypadRFID
Please pay attention to the dierent system wiring configurations that apply (described in
Section 2.1), depending on whether or not the T24-DoorMaster and external devices such
as a light are used.
1. Ensure that the seal is fitted to the keypad.
2.
Loosen the rear cover plate (using a small screwdriver
or similar tool) and remove it. You now have a clear
view of the connectors located directly on the keypad
board.
3.
Remove approximately 5 mm of insulation from each
of the cables to be connected and feed each cable
through one of the wire apertures in the housing
(piercing the rubber membrane).
Seal