94/148
T24 System Manual Part 1: Installation
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
2.4.6 Removing And Exchanging Modules
If anti-theft protection has been activated (see Section 2.3.7), you will need to switch this
o before you can remove and exchange the modules.
1.
Switching o anti-theft protection on the T24-DoorMaster:
Press both buttons on the T24-DoorMaster at the same
time for ten seconds to deactivate the anti-theft
protection for 90 seconds (blue LED blinks). After
this, the protection will be automatically reactivated.
2. Switching o anti-theft protection when there is no T24-DoorMaster: Connect
the two cables of the anti-theft protection to the 12 V power supply of the electric
door opener via a switch. Anti-theft protection is deactivated for as long as the
voltage is applied (switch on).
Caution
The anti-theft protection must be disconnected from the voltage again (switch o)
after no more than five minutes in order to avoid an overload.
Hold at the same time until
the blue LED flashes
Outdoors Indoors
Door station
Switch box
Door
12 V
Power supply
S
Comentarios a estos manuales