2.4.4 Installing The Info Module T24-Info2wire+
The info module with integrated Mx2wire+ technology is used to connect the door station
to the network via a two-wire cable such as a bell wire and has an info field with permanent
LED backlighting.
1. Ensure that the seal is fitted to the info module.
2.
Loosen the rear cover plate (using a small screwdriver
or similar tool) and remove it. You now have a clear
view of the connectors located directly on the info
module board.
3.
Remove approximately 5 mm of insulation from each
of the cables to be connected and feed each cable
through one of the
wire apertures
in the housing
(piercing the rubber membrane with the cable).
4.
Connect the two-wire cable, which leads to the separate
T24-Info2wire+ unit in the building, to the board.
• First wire to Data 1 terminal
• Second wire to Data 2 terminal
Seal